Galver

Quality Certifications

The quality of workmanship, high degree of specialization, compliance with the specific technical standards required by the aviation industry, and high organizational standards, combined with constant technical upgrading and perfecting of software and hardware systems, have resulted in a professionalism that is the strength of Galver Srl.
The competitive advantage created by Galver Srl in the manufacturing industry comes mainly from the experience gained over the years and the support of qualified personnel.

The company has established a Quality System that was first certified according to UNI EN ISO 9001 in 2006 and then, in September 2012, according to AS/EN/JISQ 9100.

For galvanic treatments, we are NADCAP accredited for the commodities “Chemical Processing” and “NonDestructive Testing.”
Regarding Non-Destructive Testing (NDT) method Liquid Penetrant Inspection (NDT PT) & Magnet Flaw Detection (NDT MT)” methods, we are qualified for the following process specifications:
  • ASTM E1417 “Standard Practice for Liquid Penetrant Testing.”
  • ASTM E1444 “Standard Practice for Magnetic Testing.

Customer qualifications

Leonardo Helicopters

  • Painting
  • Surface preparation (degreasing, grouting, sanding, etc.).
  • Galvanic Treatments (Sulfuric Acid and Sodium Dichromate Attack, Sulfuric Acid Pickling, Sealed and Unsealed Chromic Anodic Oxidation, Passivation of Corrosion Resistant Steels, Chromate Conversion Treatment of Aluminium Alloys & Brush Cadmium Plating, Electrodeposited)
  • Sandblasting (wet and dry)
  • Application of adhesive primer for bonding
  • Application of solid lubricant
  • Structural and nonstructural bonding
  • Curing
  • Non-Destructive Testing (NDT) method Liquid Penetrant Inspection (NDT PT) & Magnet Flaw Detection (NDT MT)
  • Tightening with a torque wrench
  • Final Static Balancing Tails RB EH101 ATR
  • Miscellaneous rework on parts and segments (Production, Civil Maintenance and Military Maintenance)

Leonardo Electronics

  • Anodic oxidation
  • Chrome plating of aluminum and its alloys with Trivalent Chromium

Leonardo Velivoli

Vapor phase degreasing

Rheinmetall

  • Galvanic Treatments
  • Painting
  • NDT

Avio

NDT Liquid Penetrant Inspection

Hitachi Rail

Surface Preparation and Painting

Chemical laboratory

Galver has a chemical laboratory with the necessary instruments and equipment to carry out analysis for the control of electroplating baths and electroforming bath.
It is equipped with the following equipment:

  • Atomic absorption spectrometer;
  • Electromechanical testing machine for peel, tensile and shear tests (100 KN);
  • automatic titrator;
    corrosion resistance (salt spray) testing machine;
  • mitten;
  • Vickers durometer;
  • distiller, magnetic stirrer, glassware, burettes, and various reagents for acid/base analysis and iodometry;

Measurement and control instruments

The quality of the processes and treatments performed is ensured through the use of a series of instruments that are periodically checked for calibration status through SIT centers.

We have paint and primer thickness gauges, micrometers, and a universal eddy current instrument for inspecting and finding surface, sub-surface, and hole defects.